top of page

WCX2BA & BB Thru-the-Wall Cond Unit AHRI Ratings
D.O.E. Special Space Constrained Category (Minimum SEER2 = 11.7)

WCX2BA &BB
WCX4BC

  MODEL            Fan Coil                                        AHRI      SIZE    H         W         D  

18WCX2BA       Thru-the-Wall Condensing Unit                                           32"         24"       19"
                          24HXS-X-ECM Motor Ceiling                                                10"      37 1/4"    21"      
                          19UCX-ECM Front-Return AHU                                            40"     22 1/8"  15 1/8"
24WCX2BA       Thru-the-Wall Condensing Unit                                           32"         24"       19"
                          25HXS-X-ECM Motor Ceiling AHU                                        10"     43 1/4"    21"
                          25UCX-ECM Front-Return AHU                                            40"     22 1/8" 15 1/8"      
30WCX2BA       Thru-the-Wall Condensing Unit                                           32"         24"       19"
                          30HXS-0-PSC Motor Ceiling AHU                                        10"      43 1/4"   21"
                          32UCX-ECM Front Return AHU                                            43"       22 18" 18 1/8" 

18WCX2BB      Thru-the-Wall Condensing Unit                                           28"     25 3/4"    19" 
                         19HXS-X-ECM Motor Ceiling AHU                                        10"     38 1/4"    21" 
                         19UCX-ECM Motor Front-Return AHU                                 40"     22 18"   15 1/8" 
24WCX2BB      Thru-the-Wall Condensing Unit                                           28"     25 3/4"    19"
                         24HXS-X-ECM Motor                                                             10"     37 1/4"    21"
                         25UCX-ECM Motor Front-Return AHU                                 40"     22 1/8" 15 1/8"
30WCX2BB      Thru-the-Wall Condensing Unit                                           28"     25 3/4"   19"
                         36CLX-ECM Motor Side-Return AHU                                29 3/8" 26 3/8" 26 3/8"    
                         32UCX-ECM Motor Front-Return AHU                                 43"     22 1/8" 18 1/8"

18WCX4BC      Thru-the-Wall Condensing Unit                                           23"    29 1/2"    22" 
                         19HXS-X-ECM Motor Ceiling AHU                                        10"    37 1/4"    21"
                         19UCX-ECM Motor Front-Return AHU                                 40"    22 1/8"  15 1/8"
24WCX4BC      Thru-the-Wall Condensing Unit                                           23"    29 1/2"   22"
                         30HXS-X-ECM Motor Ceiling AHU                                        10"    43 1/4"   21"
                         25UCX-ECM Motor Front-Return AHU                                 40"    22 1/8" 15 1/8"

bottom of page